VARIANT 2
VARIANT 1 Test 1. What system of building of hospitals is optimal for prophylaxis and struggle against intrahospital infections? А. Centralized system B. Centralized– block system С. Mixed system D. Decentralized system E. Block system Test 2. In what case the decentralized system of building of hospital is considered the most rational? А. In large industrial centers В. In a countryside C. At construction of the specialized hospitals D. In seismically dangerous districts E. At construction of children's hospitals
Test 3. What from the listed zones is not allocated on a hospital site? A. Zone of building B. Household (economic) zone C. Rest zone D. Zone of polyclinic E. Garden of hospital (A hospital garden)
Test 4. What allowable area of building (percent of building) site of hospital? А. More than 15 % B. No more than 15 % C. No more than 20 % D. No more than 40 % Е. No more than 25 %
Test 5. What should be the area on one bed in ward of the common type? А. 5 m2 В. 10 m2 С. 7 m2 D. 12 m2 Е. 6 m2 Test 6. Where is it necessary to place infectious department? A. On 1 floor of the medical block with a separate entrance and lock B. On a separate floor of the medical establishment with a separate department of reception C. Outside a hospital site D. In a separate building on a site of hospital Е. At a main entrance of hospital
Test 7. What subjects are most dangerous concerning transfer of intrahospital infections? А. Products of a feed(meal) and utensils B. The equipment for inhalations C. Surgical instruments and needles D. Furniture and bed-clothes E. Equipment for a narcosis
Test 8. What norm of common illuminating for filament lamps in ward of a common type: А. 50 lux В. 75 lux С. 100 lux D. 125 lux Е. 150 lux
Test 9. The frequency of rate of ventilation in ward should be: А. 1-2 В. 2-3 С. 3-4 D. 4-5 Е. 5-6
Test 10. The normal temperature of air in operational should be ( C°): А. 18-20 В. 18-22 С. 18,9-21,7 D. 22-25 Е. 23-25
Test 11. The normal frequency of influx of ventilation in operational room: А. 4 В. 5 С. 6 D. 7 Е. 8
Test 12. Subjects and the toolkit, concerning to half critical on danger of transfer of an intrahospital infection: A. Equipment for inhalations B. Equipment for a narcosis C. Catheters D. Surgical instruments and needles E. Bed-clothes and furniture
Test 13. The relative humidity of air in operational should not exceed: А. 40 % В. 45 % С. 50 % D 55 % Е. 60 %
Test 14. Difference boxing wards from wards of the common structure: A. Presence 2 entrances B. Presence of a bathroom C Presence of septums between beds D. Absence of tambour E. Presence of one entrance Test 15. What norm of the area of the hospital site is it necessary if the hospital is constructed on 50 places ( Decentralized system)? А. 60 – 80 m2 В. 80 – 100 m2 С. 100 – 140 m2 D. 140 – 200 m2 Е. 200 – 300 m2 K. 300 m2
VARIANT 2 Test 1. The zone of medical blocks is subdivided on: A. Zone of medical blocks for not infectious patients B. Zone of medical blocks for infectious patients C. Zone of a polyclinic for ambulatories D. Economical zone E. Pathoanatomical zone
Test 2. The normal FNI (factor of natural illumination) for wards: А. 0,5 % В. 1 % С. 1,5 % D. 2,0 % Е. 2,5 %
Test 3. Whether is possible consolidation of a reception of children's department with the general receptions department of a hospital? А. Yes it is В. No it is not С. It is possible only at the centralized system of construction D. It is possible only at decentralized system of construction Е. It is possible only at the mixed system of construction
Test 4. The local illumination in ward of the common structure should be: А. 50 lux В. 75 lux С. 100 lux D. 125 lux Е. 150 lux Test 5. The depth of ward should be no more: А. 3 m В. 4 m С. 5 m D. 6 m Е. 7 m
Test 6. What is normal height of ward and medical-diagnostic offices? A. Not less than 2,7 m B. Not less than 2,5 m C. Not less than 3,0 m D. Depending on a category of hospitals E. Is not standardized
Test 7. In what case placing of the operational block is optimal (specify one answer)? А. In a separate building in territory of hospital В. In a separate part of surgical department С. In the separate block connected with a building of hospital by the covered corridor D. In the main building (block) of hospital E. Near with a receptions department
Test 8. The hospitals subdivide on a structure: A. Republican B. Urban C. Regional D. Specialized E. Common of a structure Test 9. The normal speed of air movement in ward of a common structure should be: А. 0,1-0 m/sec В. 0,1-0,6 m/sec С. 0,2-0,5 m/sec D. 0,2-0,3 m/sec Е. 0,2-0,5 m/sec
Test 10. Light factor for ward should be: А. 1/3 В. 1/5 С. 1/6 D. 1/8 Е. 1/2
Test 11. The normal illuminating intensity of an operations field should be: A. Not less than 3000 lux B. Not less than 1000 lux C. Not less than 10000 lux D. 1500 - 3000 lux E. Not less than 1000 lux
Test 12. The area of ward on four beds is 21 m2. Whether it corresponds to the hygienic requirements? А. Corresponds B. Does not corresponds С. Corresponds at the mixed type of construction of a building D. Corresponds at the centralized type of construction of a building Е. Corresponds at decentralized a type of construction of a building
Test 13. The wards section of hospital is called: А. Some wards on 60 beds as a whole В. Separate ward on 2-4 beds С. Some wards on 2-4- beds D. Set of premises on 25-30 beds, E. Some wards on 60 beds as a whole
Test 14. The area operational should be: A. Not less than of 25 m2 B. Not less than of 30 m2 C. Not less than of 36 m2 D. Not less than of 40 m2 E. Not less than of 50 m2
Test 15. The area of complete boxing in infectious branch makes: А. 22 m2 В. 30 m2 С. 40 m2 D. 15 m2 Е. 50 m2
|
|||
|